ข้อมูลพื้นฐาน
ไม่ใช่ ของรุ่น
RST, RSNY, RSWY
แอปพลิเคชัน
อิเล็กทรอนิกส์
แพคเพจการขนส่ง
Corrugated Carton
รหัสพิกัดศุลกากร
3917390000
คำอธิบายสินค้า
Heat Shrink Termination for LV cables (Series Part No.: RST)The terminations are designed for 1-,2-,3-,4-,and 5-core cables with or without armour. The terminations are also applicable to 3+1,4+1 and 3+2 cables. The cable crutch is sealed by a breakout inner coated with adhesive. Heat shrink insulation tubes seal between the cable lug and the bottom of the core insulation. For single core cables only an insulation tube is needed. All materials are resistant to UV and weathering.
Selection TableVoltage | Cores | Cross section (sqmm) | Kit No. |
|
0.6/1(1.2)kV | 1,2,3,4,5 | 4-6 10-16 25-50 70-120 150-240 300-400 500 | 0.6/1kVRST-4(5,3,2)/(-1) 0.6/1kVRST-4(5,3,2)/0 0.6/1kVRST-4(5,3,2,1)/1 0.6/1kVRST-4(5,3,2,1)/2 0.6/1kVRST-4(5,3,2,1)/3 0.6/1kVRST-4(5,3,2,1)/4 0.6/1kVRST-4(3,2,1)/5 |
Indoor termination for screened,1-core polymeric insulated cables 6kV,10kV,20kV,30kV and 35kV (Series Part No.: RSNY-1)The indoor termination is designed for screened single core polymeric insulated MV cables up to 35kV. Yellow stress relief mastic is laid around the end of the screen cut. Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable screen end. Anti-tracking insulation tube and sealing tube seal between the end of the oversheath and the cable lug. Anti-tracking rain sheds lengthen surface creepage distance to ensure safety.
Selection TableNominal Voltage U0/U(Um) | Cross section (sqmm) | Kit No. | Diensions(mm) | No. of rain sheds |
L | D |
3.6/6(7.2)kV | 25-50 70-120 150-240 300-400 500-630 800-1000 1200 | 6kVRSNY-1/1 6kVRSNY-1/2 6kVRSNY-1/3 6kVRSNY-1/4 6kVRSNY-1/5 6kVRSNY-1/6 6kVRSNY-1/7 | 800 | - | 0 |
6/10(12)kV 6.35/11(12)kV 8.7/15(17.5)kV | 25-50 70-120 150-240 300-400 500-630 800-1000 1200 | 10kVRSNY-1/1 10kVRSNY-1/2 10kVRSNY-1/3 10kVRSNY-1/4 10kVRSNY-1/5 10kVRSNY-1/6 10kVRSNY-1/7 | 800 | - | 2 |
12/20(24)kV 12.7/22(24)kV | 35-50 70-120 150-240 300-400 500-630 800-1000 1200 | 20kVRSNY-1/1 20kVRSNY-1/2 20kVRSNY-1/3 20kVRSNY-1/4 20kVRSNY-1/5 20kVRSNY-1/6 20kVRSNY-1/7 | 800 | 105 105 105 140 140 140 140 | 2 |
18/30(36kV) 19/33(36kV) | 35-50 70-120 150-240 300-400 500-630 800-1000 1200 | 30kVRSNY-1/1 30kVRSNY-1/2 30kVRSNY-1/3 30kVRSNY-1/4 30kVRSNY-1/5 30kVRSNY-1/6 30kVRSNY-1/7 | 800 | 105 105 140 140 140 140 140 | 4 |
20.8/36(42)kV 26/35(42)kV | 50 70-120 150-240 300-400 500-630 800-1000 1200 | 35kVRSNY-1/1 35kVRSNY-1/2 35kVRSNY-1/3 35kVRSNY-1/4 35kVRSNY-1/5 35kVRSNY-1/6 35kVRSNY-1/7 | 800 | 140 140 140 140 140 140 140 | 4 |
Outdoor termination for screened, 1-core polymeric insulated cables 6kV,10kV,20kV,30kV and 35kV (Series Part No.: RSWY-1)The outdoor termination is designed for screened single core polymeric insulated MV cables up to 35kV. Yellow stress relief mastic is laid around the end of the screen cut. Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable screen end. Anti-tracking insulation tube and sealing tube seal between the end of the oversheath and the cable lug. Anti-tracking rain sheds lengthen surface creepage distance to ensure safety.
Selection TableNominal Voltage U0/U(Um) | Cross section (sqmm) | Kit No. | Diensions(mm) | No. of rain sheds |
L | D |
3.6/6(7.2)kV | 25-50 70-120 150-240 300-400 500-630 800-1000 1200 | 6kVRSWY-1/1 6kVRSWY-1/2 6kVRSWY-1/3 6kVRSWY-1/4 6kVRSWY-1/5 6kVRSWY-1/6 6kVRSWY-1/7 | 800 | 105 105 105 105 140 140 140 | 3 |
6/10(12)kV 6.35/11(12)kV 8.7/15(17.5)kV | 25-50 70-120 150-240 300-400 500-630 800-1000 1200 | 10kVRSWY-1/1 10kVRSWY-1/2 10kVRSWY-1/3 10kVRSWY-1/4 10kVRSWY-1/5 10kVRSWY-1/6 10kVRSWY-1/7 | 800 | 105 105 105 105 140 140 140 | 3 |
12/20(24)kV 12.7/22(24)kV | 35-50 70-120 150-240 300-400 500-630 800-1000 1200 | 20kVRSWY-1/1 20kVRSWY-1/2 20kVRSWY-1/3 20kVRSWY-1/4 20kVRSWY-1/5 20kVRSWY-1/6 20kVRSWY-1/7 | 800 | 105 105 105 140 140 140 140 | 4 |
18/30(36kV) 19/33(36kV) | 35-50 70-120 150-240 300-400 500-630 800-1000 1200 | 30kVRSWY-1/1 30kVRSWY-1/2 30kVRSWY-1/3 30kVRSWY-1/4 30kVRSWY-1/5 30kVRSWY-1/6 30kVRSWY-1/7 | 800 | 105 105 140 140 140 140 140 | 6 |
20.8/36(42)kV 26/35(42)kV | 50 70-120 150-240 300-400 500-630 800-1000 1200 | 35kVRSWY-1/1 35kVRSWY-1/2 35kVRSWY-1/3 35kVRSWY-1/4 35kVRSWY-1/5 35kVRSWY-1/6 35kVRSWY-1/7 | 800 | 140 140 140 140 140 140 140 | 6 |
Indoor termination for screened,3-core polymeric insulated cables 6kV,10kV,20kV,30kV and 35kV (Series Part No.: RSNY-3)The indoor termination is designed for screened single core polymeric insulated MV cables up to 35kV. Yellow stress relief mastic is laid around the end of the screen cut. Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable screen end. All phase cores are covered with anti-tracking insulation tube and sealing tube. Anti-tracking rain sheds lengthen surface creepage distance to ensure safety. The crutch area is sealed and protected with an adhesive-coated breakout which is installed over the cores at the end of oversheath.
Selection TableNominal Voltage U0/U(Um) | Cross section (sqmm) | Kit No. | Diensions(mm) | No. of rain sheds |
L | D |
3.6/6(7.2)kV | 25-50 70-120 150-240 300-400 500-630 | 6kVRSNY-3/1 6kVRSNY-3/2 6kVRSNY-3/3 6kVRSNY-3/4 6kVRSNY-3/5 | 750 | - | 0 |
6/10(12)kV 6.35/11(12)kV 8.7/15(17.5)kV | 25-50 70-120 150-240 300-400 500-630 | 10kVRSNY-3/1 10kVRSNY-3/2 10kVRSNY-3/3 10kVRSNY-3/4 10kVRSNY-3/5 | 750 | - | 0 |
12/20(24)kV 12.7/22(24)kV | 35-50 70-120 150-240 300-400 500-630 | 20kVRSNY-3/1 20kVRSNY-3/2 20kVRSNY-3/3 20kVRSNY-3/4 20kVRSNY-3/5 | 900 | 105 105 105 140 140 | 6 |
18/30(36kV) 19/33(36kV) | 35-50 70-120 150-240 300-400 500-630 | 30kVRSNY-3/1 30kVRSNY-3/2 30kVRSNY-3/3 30kVRSNY-3/4 30kVRSNY-3/5 | 1100 | 105 105 140 140 140 | 12 |
20.8/36(42)kV 26/35(42)kV | 50 70-120 150-240 300-400 500-630 | 35kVRSNY-3/1 35kVRSNY-3/2 35kVRSNY-3/3 35kVRSNY-3/4 35kVRSNY-3/5 | 1100 | 140 140 140 140 140 | 12 |
Outdoor termination for screened,3-core polymeric insulated cables 6kV,10kV,20kV,30kV and 35kV (Series Part NO.: RSWY-3)The outdoor termination is designed for screened single core polymeric insulated MV cables up to 35kV. Yellow stress relief mastic is laid around the end of the screen cut. Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable screen end. All phase cores are covered with anti-tracking insulation tube and sealing tube. Anti-tracking rain sheds lengthen surface creepage distance to ensure safety. The crutch area is sealed and protected with an adhesive-coated breakout which is installed over the cores at the end of oversheath.
Selection TableNominal Voltage U0/U(Um) | Cross section (sqmm) | Kit No. | Diensions(mm) | No. of rain sheds |
L | D |
3.6/6(7.2)kV | 25-50 70-120 150-240 300-400 500-630 | 6kVRSWY-3/1 6kVRSWY-3/2 6kVRSWY-3/3 6kVRSWY-3/4 6kVRSWY-3/5 | 900 | 105 105 105 105 140 | 6 |
6/10(12)kV 6.35/11(12)kV 8.7/15(17.5)kV | 25-50 70-120 150-240 300-400 500-630 | 10kVRSWY-3/1 10kVRSWY-3/2 10kVRSWY-3/3 10kVRSWY-3/4 10kVRSWY-3/5 | 900 | 105 105 105 105 140 | 6 |
12/20(24)kV 12.7/22(24)kV | 35-50 70-120 150-240 300-400 500-630 | 20kVRSWY-3/1 20kVRSWY-3/2 20kVRSWY-3/3 20kVRSWY-3/4 20kVRSWY-3/5 | 900 | 105 105 105 140 140 | 12 |
18/30(36kV) 19/33(36kV) | 35-50 70-120 150-240 300-400 500-630 | 30kVRSWY-3/1 30kVRSWY-3/2 30kVRSWY-3/3 30kVRSWY-3/4 30kVRSWY-3/5 | 1100 | 105 105 140 140 140 | 18 |
20.8/36(42)kV 26/35(42)kV | 50 70-120 150-240 300-400 500-630 | 35kVRSWY-3/1 35kVRSWY-3/2 35kVRSWY-3/3 35kVRSWY-3/4 35kVRSWY-3/5 | 1100 | 140 140 140 140 140 | 18 |
ที่อยู่:
2nd Floor, Phase 3, Woer Industrial Park, Lanjing North Road, Longtian St, Shenzhen, Guangdong, China
ประเภทของธุรกิจ:
ผู้ผลิต/โรงงานผลิต
ขอบเขตธุรกิจ:
ไฟฟ้าและอุปกรณ์อิเล็กทรอนิกส์
การรับรองของระบบการจัดการ:
ISO 9001, ISO 9000
แนะนำบริษัท:
Woer มีผลิตภัณฑ์หลากหลายประเภทสำหรับการใช้งานที่หลากหลายโดยใช้เทคโนโลยีการหดความร้อนการหดความเย็นและการใช้งานแบบเย็น เทคโนโลยี Woer ใช้วัสดุเทอร์โมพลาสติกโพลิเมอร์สูตรพิเศษหรือยางซิลิโคนคุณภาพสูง สูตรวัสดุได้รับการออกแบบเลือกและผสมในโรงงานของเราเอง การควบคุมกระบวนการที่ซับซ้อนระหว่างการอัดขึ้นรูปด้วยการฉีดการเชื่อมโยงหลายจุดและการขยายช่วยให้มั่นใจได้ถึงคุณภาพและความน่าเชื่อถือที่สูงของผลิตภัณฑ์ของเรา
นวัตกรรมคือจิตวิญญาณขององค์กรที่ใช้เทคโนโลยีระดับสูง เพื่อให้บรรลุเป้าหมายนี้เราจึงได้จัดตั้งห้องปฏิบัติการวัสดุไว้หลายแห่งและห้องแล็บทดสอบแรงดันไฟฟ้าสูงที่มีอุปกรณ์ครบครันสองห้องพร้อมด้วยการทนต่อแรงดันไฟฟ้า AC ได้สูงถึง 1200kV ห้องทดลองทั้งหมดได้รับการพิสูจน์ตัวตนโดย CNAS ในปี 2011 นอกจากนี้วิศวกรไฟฟ้าช่างวัสดุและเครื่องกลต่างก็กำลังทำงานร่วมกับทีมงานข้ามสายงานที่มุ่งเน้นไปที่เทคโนโลยีใหม่ๆและการพัฒนาผลิตภัณฑ์