ข้อมูลพื้นฐาน
ไม่ใช่ ของรุ่น
FCS521-SD-5V or FCS521-SD-10V
Certification
CE&RoHS, UL&cUL
Enclosure Material
UL 94 V -0 Flammability Rated, ABS Plastic Housi
Input Current Ranges
0-5, 10, 20A (0-200A Pre-Calibratable by Factory)
Output (DC)
0-5V, 0-10V(Selectable by Customer)
Power Supply
No Need, Self-Powered
คำอธิบายสินค้า
Handbook of Transducers
Application
Current transducer measure power and monitor operations as well as monitoring changing products variables.
Feature of Current Transducer:
Three ranges per unit reduces inventory by selecting jumper or none. No field adjustment necessary, factory calibrated. Average measurement is equivalent to True RMS for pure sine waves for the 0~5V, 0~10V no need power supply. 4~20mA series True RMS measurement for sine waves or variable frequency drives for the series Input or Output isolation through current transformer solid-state reliability.
Specifications:
Amperage Range: 0~200A AC
Power supply: 15~42 V DC at sensor(loop powered)
Operating Temperature: -30~+70 Degrees Centigrade
Input Current Ranges(3 selectable ranges): 0-10/0-200/0-50 AMPS or 0-50/0-100/0-200 AMPS.
Operating Humidity: 0-95% RH, non-condensing.
Frequency: 40~400Hz
Approvals: UL & cUL CE & RoHS
Maximum Input
Current:
10/20/50 AMP ranges - 80/120/200 AMPS continuous
50/100/200 AMP ranges -175/300/400 AMPS continuous
Protection Circuit Reverse voltage protected and output limited.
Response Time: 250 MS (0-90%)
Wiring Solid Core: Barrier strip AC Conductor Hole
Split Core/Solid Core:
Enclosure Material UL 94 V -0 flammability rated, ABS plastic housing.
Output Signal & Accuracy: 4-20 mA represents 0-100% of current span, better than ± 1% FS on all three ranges.
Risk of Shock
Disconnect power supply before making electrical connections. Contact with components carrying hazardous voltage can cause electrical shock and may result in severe personal injury or death. Ensure all installations are in compliance with applicable electrical codes and that the installation is completed by qualified installers familiar with the standards and proper safety procedures for hegh-voltage installation. Never rely on status indicating devices only to determine if power ispresent in a conductor. Ensure the range selection jumper is installed in the correct position for the current being monitored.
Attention:
1\0-5V, 0-10V output do not need power supply.
2\Excessive current can damage the sensor. See below for information on setting the jumpers: A). Install the Split-Core over the conductor to be monitored and close the sensor until it latches, ensuring that the two halves are properly aligned.
B). Operation of the sensor will be impaired, if any dirt particles prevents good contact between the core pieces when the divice is closed, keep the sensor clean when it is opened.
Mounting:
Mount the switch in a suitable location using the two mounting holes in the base of the unit. The conductor may be looped more than once through the sensor to multiply the sensitivity but this also divides the maximum currents. For example, on the 0-200 AMP scale, if the conductor is looped through twice, the maximum current will be 100 AMPS now. Connect the output circuit to the two screw terminals using ring or for type terminals. Note polarity as indicated on the device label. To allow field calibration, all devices have easily accessible calibration pots. The devices may be calibrated to custom.
Model | input range AC | accuracy | output DC | FCS521-SD-5V | 0- 10A 20A 50A | 1% | 0- 5V | FCS2151-SD-5V | 0-100A,150A,200A | 1% | 0-5V | FCS521-SP-5V | 0-10A 20A 50A | 1% | 0-5V | FCS2151-SP-5V | 0-100A 150A 200A | 1% | 0-5V | FCS521-SD-10V | 0-10A 20A 50A | 1% | 0-10V | FCS2151-SD-10V | 100A 150A 200A | 1% | 0-10V | FCS521-SP-10V | 0-10A 20A 50A | 1% | 0-10V | FCS2151-SP-10V | 100A 150A 200A | 1% | 0-10V | FCS521-SD-420E | 0-10A 20A 50A | 1% | 4-20mA | FCS2151-SD-420E | 100A 150A 200A | 1% | 4-20mA | FCS521-SP-420E | 0-10A 20A 50A | 1% | 4-20mA | FCS2151-SP-420E | 100A 150A 200A | 1% | 4-20mA | FCS521-SD-420T | 0-10A 20A 50A | 1% | 4-20mA RMS | FCS2151-SD-420T | 100A 150A 200A | 1% | 4-20mA RMS | FCS521-SP-420T | 0-10A 20A 50A | 1% | 4-20mA RMS | FCS2151-SP-420T | 100A 150A 200A | 1% | 4-20mA RMS | SD=solid core SP=split core |
|
ที่อยู่:
Luopu St., Panyu, Guangzhou, Guangdong, China
ประเภทของธุรกิจ:
ผู้ผลิต/โรงงานผลิต, รายบุคคล/SOHO
ขอบเขตธุรกิจ:
บริการ, ผลิตภัณฑ์คอมพิวเตอร์, อุปกรณ์อิเล็กทรอนิกส์เพื่อการบริโภค, อุปกรณ์และส่วนประกอบอุตสาหกรรม, เครื่องมือและเครื่องวัด, ไฟฟ้าและอุปกรณ์อิเล็กทรอนิกส์, ไฟและแสงสว่าง
แนะนำบริษัท:
ตัวแปลงสัญญาณปัจจุบัน
ซีรี่ส์จะวัดกำลังและตรวจสอบการทำงานรวมทั้งตรวจสอบตัวแปรผลิตภัณฑ์ที่เปลี่ยนแปลง
คุณสมบัติของหัวโซน่าร์ปัจจุบัน :
สามช่วงต่อเครื่องช่วยลดการคิดค้นโดยการเลือกจัมเปอร์หรือไม่มีเลย ไม่จำเป็นต้องปรับฟิลด์ปรับเทียบจากโรงงาน
ข้อมูลจำเพาะ :
ติดต่อ
กับบุคคลสำคัญ : Jackie Fang
Current Switches
ซีรี่ส์นี้มีวัตถุประสงค์เพื่อตรวจสอบสถานะการทำงานของพัดลมปั๊มและมอเตอร์ สวิตช์ที่มีแหล่งจ่ายไฟในตัวเหล่านี้สามารถแขวนหรือยึดโดยตรงกับสายเคเบิลหรือสายไฟได้ สำหรับการติดตั้งที่มีอยู่สามารถติดตั้งแกนแยกได้โดยไม่ต้องถอดสายเคเบิล ไฟแสดงสถานะ LED ให้การยืนยันด้วยภาพว่ากระแสไฟฟ้าไหลผ่านแกน มีทั้งจุดตั้งค่าแบบคงที่และแบบปรับได้ รุ่นที่ปรับได้จะปรับค่าที่ตั้งได้อย่างง่ายดายด้วยโพเทนชิออมิเตอร์