Product Name
Aqueous Ammonia Nitrogen Transmitter
เครื่องหมายการค้า
Rainbow
คำอธิบายสินค้า
Water Quality Sensor Aqueous Ammonia Nitrogen ion Transmitter
RK-3001-NH4
Product Introduction1.Product overviewRK-3001-NH4 is one of the intelligent online chemical analysis instruments. It uses a PVC membrane ion selector to test the ammonium content in the water. It can be fast, simple, precise and economical. The electrode is an electrochemical sensor for measuring dissolved ammonia, ammonium salts, nitrate nitrogen, total nitrogen and organic nitrogen in aqueous solutions.This product is equipped with a waterproof housing, which can convert the signal of the aqueous solution into a standard 485/4-20mA/0-10V signal through digital setting and analysis. The product does not need to be calibrated once, and can be used when you get it.2.Main parametersparameter name | Parameter content |
DC power supply | 12-24V DC |
Power consumption | ≤0.15W(@12V DC , 25ºC) |
measurement accuracy | 5%F.s |
Ammoniumion range | 0-100ppm |
Ammoniumion resolution | 0.01ppm |
output signal | 485/4-20mA/0-10V |
Water temperature | -10ºC-80ºC(Manual / Auto) |
Water temperature accuracy | 0.1ºC |
Water temperature resolution | 0.1 |
Product Size | 110×85×44mm3 |
Probe size | 155mm*12mm(Length * diameter) |
Probe cable length | 5 meter(default) |
Interferingion | K+ |
3. System framework diagram3.1 485 interface frame diagramThe sensor can be connected and used alone. First, use a 12V DC power supply. The device can be directly connected to a 485 interface PLC, or it can be connected to a single-chip microcomputer through a 485 interface chip. The single-chip microcomputer and PLC can be programmed through the modbus protocol specified later and can be used with the sensor. At the same time, use USB to 485 to connect to the computer, and use the sensor configuration tool provided by our company for configuration and testing.This product can also be used by combining multiple sensors on a single 485 bus. Please follow the "485 bus field wiring rules" (see appendix) when performing 485 bus combination.In theory, one bus can connect more than 16 485 sensors, if you need to connect more 485 sensors,You can use the 485 repeater to expand more 485 devices, the other end is connected to the PLC with the 485 interface, and the single-chip microcomputer is connected through the 485 interface chip.Or use USB to 485 to connect to the computer, and use the sensor configuration tool provided by our company for configuration and testing.3.2 Frame diagram of analog interfaceThe analog interface can be directly connected to the PLC data module, or the signal can be processed by the single-chip microcomputer, as shown in the figure below:Hardware Connection1.Inspection before equipment installationPlease check the equipment list before installing the equipment:name | Quantity |
High-precision sensor | 1 set |
12V waterproof power supply | 1 set (optional) |
Warranty card/certificate | 1 serving |
2.Interface descriptionThe power interface can be a wide voltage power input of 12-24V. The product pays attention to the positive and negative of the signal line, and do not reverse the positive and negative of the signal line.Wiring mode of 485 interface sensor: | Thread color | Description |
power supply | brown | Power supply positive (12-24VDC) |
| black | Power negative |
Communication | Yellow (gray) color | 485-A |
| blue | 485-B |
Analog interface sensor wiring mode: | Thread color | Description |
power supply | brown | Power supply positive (12-24VDC) |
| black | Power negative |
Communication | Yellow (gray) color | Voltage/current output positive |
| blue | Voltage/current output negative |
The factory default provides 5 meters long wire, customers can extend the wire as needed or wire in order.3.Installation instructionsThis meter is wall-mounted.Please install it on the wall and try to avoid wind, rain and direct sunlight.In order to prevent the water temperature inside the instrument from rising, please install it in a well-ventilated place.When installing the instrument, please do not tilt it left or right, try to install it horizontally.The electrode is a very precise component, and the correct installation method must be used. The wrong installation method will cause the electrode to be damaged or irreversibly damaged.Electrode adopts pipeline installation. Immersion type. Flange installation is all possible.Please do not put the electrode directly into the water, you should choose the electrode mounting bracket or the flow cup to fix it.Before installation, be sure to use raw material tape (3/4 thread) to do a waterproof seal to prevent water from entering the electrode and causing short circuit of the electrode cable.
During the water cut, make sure that the electrode is immersed in the test liquid or wear a protective cap with a built-in protective liquid. In winter, the water temperature is low and the water is stopped for a long time. An antifreeze device should be added or returned to the room for storage.Otherwise, the service life will be shortened.485 interface communication protocol1.Basic communication parametersparameter | content |
coding | 8-bit binary |
Data bit | 8-bit |
Parity bit | no |
Stop bit | 1 person |
Wrong calibration | CRC lengthy cyclic code |
Baud rate | 2400bps/4800bps/9600 bps Can be set, the factory default is 9600bps |
coding | 8-bit binary |
2.Data frame format definitionAdopt Modbus-RTU communication protocol, the format is as follows:
Initial structure >= 4 bytes of time
Address code = 1 byte
Function code = 1 byte
Data area = N bytes
Error check = 16-bit CRC code
End structure >= 4 bytes time
Address code: the address of the transmitter, which is unique in the communication network (factory default 0x01).
Function code: The command function prompt sent by the host, this transmitter only uses the function code 0x03 (read memory data).
Data area: The data area is the specific query data area, pay attention to the 16bits data high byte first.
CRC code: two-byte check code.
Interrogation frame:address code | function code | Register start address | Register length | Check code low bit | High bit of check code |
1 byte | 1 byte | 2 byte | 2 byte | 1 byte | 1 byte |
Reply frame:address code | function code | Number of valid bytes | Data area | Second data area | Nth data area |
1 byte | 1 byte | 1 byte | 2 byte | 2 byte | 2 byte |
3. Register addressRegister address | PLC configuration address | content | operating |
0001H | 40002 | Water temperature (unit: 0.1ºC) | Read only |
0002H | 40003 | Ammonia nitrogen (unit: 0.01ppm) | Read only |
0100H | 40101 | Device address (0-252) | Read and write |
0101H | 40102 | Baud rate (2400/4800/9600) | Read and write |
4. Communication protocol example and explanation4.1 Read the ammonia nitrogen value of the device address 0x01
Interrogation frame:address code | function code | Register start address | Register length | Check code low bit | High bit of check code |
0x01 | 0x03 | 0x00,0x02 | 0x00,0x01 | 0x25 | 0xCA |
Response frame (for example, read the ammonia nitrogen value is 1.89ppm):address code | function code | Number of valid bytes | Ammonia value | Check code low bit | High bit of check code |
0x01 | 0x03 | 0x02 | 0x00 0xBD | 0x78 | 0x35 |
Ammonia nitrogen:
00BD H (hexadecimal) = 189 => ammonia nitrogen = 1.89ppm4.2 Read the water temperature value of the device address 0x01
Interrogation frame:address code | function code | Register start address | Register length | Check code low bit | High bit of check code |
0x01 | 0x03 | 0x00,0x01 | 0x00,0x01 | 0xD5 | 0xCA |
Reply frame:address code | function code | Number of valid bytes | Water temperature value | Check code low bit | High bit of check code |
0x01 | 0x03 | 0x02 | 0x00 0xAF | 0xDB | 0xBF |
Water temperature:
00AF H(hexadecimal)=175=>water temperature=17.5ºC4.3 Read device address 0x01 water temperature, ammonia nitrogen concentration value
Interrogation frame:address code | function code | Register start address | Register length | Check code low bit | High bit of check code |
0x01 | 0x03 | 0x00,0x01 | 0x00,0x02 | 0x95 | 0xCB |
Reply frame:address code | function code | Number of valid bytes | Water temperature value | Ammonia value | Check code low bit | High bit of check code |
0x01 | 0x03 | 0x04 | 0x01 0x1b | 0x00 0x28 | 0xDB | 0xBF |
Water temperature:
011B H(hexadecimal)=283=>water temperature=28.3ºC
Ammonia nitrogen:
0028 H(Hexadecimal)=40=>Ammonia nitrogen=0.40ppmAnalog Wiring InstructionsThe analog sensor wiring is simple, just connect the wire to the designated port of the device. The device supports 3/4 wire connection.1.Typical four-wire wiring methodThe following figure shows the wiring method of current sensor. Connect the power cord (brown wire and black wire) of the sensor to the power source;The yellow (gray) color line of the sensor is the signal positive when the signal is connected to the acquisition device, and the current flow is from the sensor to the acquisition device;The blue line of the sensor is the negative signal when the signal is connected to the current acquisition device, and the current flow is from the acquisition device to the sensor.The following figure shows the wiring method of voltage type sensor. Connect the power cord (brown wire and black wire) of the sensor to the power supply;The yellow (gray) wire of the sensor is the signal positive of the signal being connected to the acquisition device, and the voltage of the yellow (gray) wire is the output voltage;The blue line of the sensor is the negative signal when the signal is connected to the voltage acquisition device. The voltage of the blue line is the reference voltage, which is 0V consistent with the voltage of the black line.2. Typical three-wire wiring method
For typical three-wire wiring, compared to four-wire wiring, the blue wire can be omitted. In the sensor, the blue wire and the black wire are short-circuited in the sensor, so the blue wire can be omitted.
For the three-wire current connection method, after connecting the power cord (brown wire and black wire) of the sensor to the power supply, only the yellow (gray) wire of the sensor is connected to the signal positive of the current acquisition device.For the three-wire voltage connection mode, after connecting the sensor's power cord (brown wire and black wire) to the power supply, only the yellow (gray) wire of the sensor is connected to the signal positive of the voltage acquisition device.Meaning and Conversion of Analog Parameters1. Analog 4-20mA current outputCurrent value | Ammonia |
4mA | 0 |
20mA | full range |
The calculation formula is P(ammonia nitrogen)=(I(current)-4mA)*(full scale)/16mA
The unit of I is mA. 4mA represents 0 point, and 20mA represents the maximum range linear conversion.
2. Analog 0-10V voltage outputVoltage value | Ammonia |
0V | 0 |
10V | full range |
The calculation formula is P (ammonia nitrogen) = V (voltage) * (full scale)/5000mV
The unit of V is mV. Please use 0V to represent 0 points and 10V to represent the maximum range linear conversion.
3. Analog 0-5V voltage outputVoltage value | Ammonia |
0V | 0 |
5V | full range |
The calculation formula is P (ammonia nitrogen) = V (voltage) * (full scale)/10000mV
The unit of V is mV. Please use 0V to represent 0 points and 10V to represent the maximum range linear conversion.
ที่อยู่:
No. 9 Dadong Rd, Jinan, Shandong, China
ประเภทของธุรกิจ:
ผู้ผลิต/โรงงานผลิต
ขอบเขตธุรกิจ:
สุขภาพและยา, อุปกรณ์อิเล็กทรอนิกส์เพื่อการบริโภค, อุปกรณ์และส่วนประกอบอุตสาหกรรม, เครื่องมือและเครื่องวัด, ไฟฟ้าและอุปกรณ์อิเล็กทรอนิกส์
การรับรองของระบบการจัดการ:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, OHSAS/ OHSMS 18001, IATF16949, HSE, ISO 14064, QC 080000, GMP, BSCI, ANSI/ESD
แนะนำบริษัท:
Jinan Rainbow Technology เป็นองค์กรที่ใช้เทคโนโลยีขั้นสูงที่มีเซ็นเซอร์ MEMS และเป็นศูนย์กลางของพลังงาน บริษัทก่อตั้งขึ้นในเมือง Jinan เมือง Shandong ประเทศจีนและมีศูนย์วิจัยและพัฒนาอยู่ในเมืองนิวยอร์กประเทศสหรัฐอเมริกา
ผลิตภัณฑ์ของเรามีบทบาทสำคัญในการเปลี่ยนผ่านไปสู่การประหยัดพลังงานและสิ่งแวดล้อมที่สะอาดสามารถนำไปใช้งานได้อย่างกว้างขวางในหลายสาขาเช่นไฮโดรเจนเซลล์เชื้อเพลิงอุปกรณ์ทางการแพทย์การฟอกอากาศอุปกรณ์ตรวจจับก๊าซแบตเตอรี่ลิเธียมการตรวจสอบความปลอดภัยของไฮโดรเจนมีการรั่วซึมบ้านอัจฉริยะ และการรักษาความปลอดภัย IoT เพื่อตอบสนองความต้องการด้านความปลอดภัยสุขภาพและการประหยัดพลังงาน
ด้วยนวัตกรรมทางเทคโนโลยีอย่างต่อเนื่องเราจึงขับเคลื่อนการเปลี่ยนผ่านของ Clean Energy และมอบวัสดุที่มีการแข่งขันมากขึ้นให้กับลูกค้าของเรา เรามีความสามารถหลักในการออกแบบการผลิตและการทดสอบเพื่อมอบผลิตภัณฑ์ที่มีความเที่ยงตรงสูงและเชื่อถือได้สูงและโซลูชันแบบหยุดเดียวให้กับลูกค้า
บริษัทของเรามีสิทธิบัตรสิ่งประดิษฐ์หลักและผ่านการรับรองระบบด้านคุณภาพ ISO 9001 ผลิตภัณฑ์ของเราสอดคล้องตามมาตรฐาน RoHS และตรงตามมาตรฐานการปกป้องสิ่งแวดล้อม
ด้วยเป้าหมายของการเป็นผู้นำด้านเทคโนโลยีเรามุ่งมั่นที่จะส่งเสริมการพัฒนาไฮโดรเจนพลังงานด้วยจิตวิญญาณของ " การปกป้องบ้านด้วยเทคโนโลยีหลักและนวัตกรรมเพื่อการเปลี่ยนแปลงชีวิต "