ข้อมูลพื้นฐาน
คำอธิบายสินค้า
Shanghai Pingkai Automation Equipment Co., Ltd. is a high-tech enterprise specialized in the sales of industrial control automation products, system integration, electrical equipment sales and electromechanical equipment sales
Siemens programmable controller S7-200CN ET-200 S7-200 S7-300 S7-400 S7-1200 S7-1500 smartS7-200
Siemens touch screen OP77-TP series MP277 MP377 TD200-TD400C
Siemens communication accessories DP cable Ethernet cable DP connector communication card
Siemens motor V60-V80 servo motor 1FT servo motor Bede motor 1FK motor
Siemens inverter V10 series MM440 series G110 series G120 series
Siemens CNC system 810D system 840D system 808D 8404DSL
Siemens frequency converter series: MM420, MM430, MM440, G110, G120. MIDASTER series
Siemens full digital DC speed regulating device 6RA23, 6RA24, 6RA28, 6RA70, 6SE70 series
Siemens actuator, burner, controller, electric eye, flame detector, module, operation panel, etc
Siemens SQN, SQM, AGG, LFL, LME, LMV, QRA, SKP, VGD, VGF, VRD
LFL1.322---Gas burner for fixed air heater, t1=36s, TSA=2s, t9=2s, AC230V minimum order quantity 10 piecesSIEMENS program controller:
LGB series (LGB21.130A27, LGB21.230A27, LGB21.330A27, LGB22.230B27
LGB22.330A27,LGB22.330A17)
LMG series (LMG21.330B27, LMG22.330B27, LMG25.330B27)
LM series (LM24.255B2, LM44.255C2)
LA series (LA24.171B27, LA44.252A27)
LAL series (LAL1.25, LAL2.25, LAL2.65,)
LFL series (LFL1.322, LFL1.333, LFL1.335, LFL1.622, LFL1.635, LFL1.638)
LK series (LK16.250A27)
LGK series (LGK16.333A27, LGK16.335A27, LGK16.622A27)
LME series (LME11.330A2, LME21.330A2, LME22.232A2, LME39.100A2
LME39.400A2)
LEV series (LEC1/8892)
LAE series (LAE10, LAE1/8865
8. When the fan is not used, an AGK25 must be connected to the terminal 3 of the controller, otherwise the burner cannot be started reliably.
9. For safety, connect the neutral conductor to the neutral distributor or terminal 2 at the bottom of the insertion block. As shown below, the burning elements (fan, ignition transformer and gas valve), as listed in Figure 74314, must be connected to the neutral conductor.
10. The connection between the neutral wire and terminal 2 is pre-wired at the bottom of the control unit.
LFL series gas burner controller LFL1.122 Siemens, Germany, features and functions:
1. This device allows the burner to be purged with or without rear purging.
2. The fan motor current is less than 4A and the starting current is 20A, which can be directly connected.
3. Control the switch and small of the output damper actuator separately.
4. Monitor the damper control to ensure that there is rated air volume during the front purging. Check the start position is closed or the low load position is small. The burner start procedure will be suspended when the actuator does not drive the damper to the predetermined position after the start position is open and the front purging time is over.
5. Test the function of air pressure monitoring before starting and purging until the control shutdown stage.
6. The control output of the individual ignition fuel valve is cut off after the end of the second safety time.
7.2 fuel release control outputs have the third control output or load control if necessary.
8. The safety time can be increased from 2.5 seconds to 5 seconds by simple measures when the series 1 program controller is directly ignited. See the safety time provided in the engineering notes to adapt to the local safety regulations.
9. When the load control is started, the control output of the damper actuator is independent of other control part circuits.
10. Connect the remote reset device remote reset and remote emergency shutdown
LFS1.21A2 - LFS1.21A2 flame control device
LFL1.122 - Gas burner for instantaneous evaporation generator, t1=10 s, TSA=2 s, t9=2 s, AC230 V
LFL1.322 -- Gas burner for fixed air heater, t1=36s, TSA=2s, t9=2s, AC230V minimum order quantity 10 pieces
LFL1.333 - Automatic combustion (gas), t1=31s, TSA=3s, t9=3s, AC230V minimum order quantity 10
LFL1.335--Gas burner, t1=37s, TSA=2.5 s, t9=5 s, AC230 V
LFL1.335-110V--Gas burner, t1=37s, TSA=2.5 s, t9=5 s, AC110V
LFL1.622--Gas burner, t1=65 s, TSA=2 s, t9=2 s, AC230 V
LFL1.635--Gas burner, t1=66s, TSA=2.5 s, t9=5 s, AC230V
LFS1.21A2-- flame control device
ที่อยู่:
Building 8, No. 8188, Daye Road, Shanghai, China
ประเภทของธุรกิจ:
ผู้ผลิต/โรงงานผลิต
ขอบเขตธุรกิจ:
การขนส่ง, บรรจุภัณฑ์และการพิมพ์, สิ่งทอ, สุขภาพและยา, อุปกรณ์และส่วนประกอบอุตสาหกรรม, เคมีภัณฑ์, เครื่องจักรการผลิตและแปรรูป, เครื่องมือและเครื่องวัด, โลหการ แร่ และพลังงาน, ไฟฟ้าและอุปกรณ์อิเล็กทรอนิกส์
แนะนำบริษัท:
บริษัท Shanghai Pingkai Automation Equipment Co., Ltd. เป็นบริษัทที่มีความเชี่ยวชาญด้านเทคโนโลยีขั้นสูงในการจำหน่ายผลิตภัณฑ์ระบบควบคุมอัตโนมัติสำหรับอุตสาหกรรมการรวมระบบการขายอุปกรณ์อิเล็กทรอนิกส์และการขายอุปกรณ์เครื่องกลไฟฟ้า
อิน 200
เวอร์เตอร์ของ 200
Siemens Programmable Controller S7-200CN ET-4 S7-7 S7-6 S7-6 300 S7-6 400 S7-6 S7-300 1500 S7-TP series MP277 TD357 TD35-TD400C อุปกรณ์เสริมในการสื่อสาร DP การ์ดสื่อสารสายเชื่อมต่อมอเตอร์อีเธอร์เน็ต / มอเตอร์สื่อสาร 200 Sony V60-V80 เซอร์โวมอเตอร์เซอร์โวมอเตอร์ 1200 ซีรี่ส์ BV10
G120 ซีรี่ส์
ระบบ CNC ของ Siemens 810D ระบบ 8840D 808D 8404DSL
Siemens ซีรี่ส์ : mm420, mm430, mm440, G110, G120 MIDASTER series
Siemens Full Digital DC SPEED conventing device 6RA23, 6RA24, 6RA28, 6RA70, 6RAID
70, 6SE70 series ตัวกระตุ้นไฟของ Siemens, เครื่องควบคุม , ห่วงไฟฟ้า , อุปกรณ์ตรวจจับเปลวไฟ โมดูลแผงควบคุมฯลฯ