• Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery
  • Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery
  • Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery
  • Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery
  • Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery
  • Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery

Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery

After-sales Service: on Line
Warranty: 1 Year
ชื่อผลิตภัณฑ์: อุปกรณ์จ่ายขวดด้านบน
สี: สีขาว
หมายเลขรุ่น: Dispensmate-PRO
ระดับเสียง: 0.5 มล

ติดต่อซัพพลายเออร์

บริษัทการค้า
สมาชิกระดับโกลด์ อัตราจาก 2024

ซัพพลายเออร์ที่มีใบอนุญาตการทำธุรกิจ

Beijing, จีน
ผู้นำเข้าและส่งออก
ซัพพลายเออร์มีสิทธินำเข้าและส่งออก
ทางเลือกของผู้ซื้อซ้ำสูง
ผู้ซื้อมากกว่า 50% เลือกซัพพลายเออร์ซ้ำแล้วซ้ำอีก
ทีมงานที่มีประสบการณ์
ซัพพลายเออร์มีพนักงานการค้าต่างประเทศ 5 คน และเจ้าหน้าที่ 4 คนที่มีประสบการณ์การค้าต่างประเทศมากกว่า 6 ปี
ประสบการณ์การจัดนิทรรศการ
ซัพพลายเออร์ได้เข้าร่วมงานแสดงสินค้าแบบออฟไลน์ คุณสามารถตรวจสอบ Audit Report สำหรับข้อมูลเพิ่มเติม
เพื่อดูป้ายกำกับความแข็งแกร่งที่ได้รับการยืนยันทั้งหมด (15)
  • ภาพรวม
  • OVERVIEW
  • Product Feature
  • Specification
  • Application Scenes
  • FAQ
  • Company Profile
  • Certifications
ภาพรวม

ข้อมูลพื้นฐาน

ไม่ใช่ ของรุ่น
SafeVac
วัสดุ
พลาสติก
แพคเพจการขนส่ง
Carton
เครื่องหมายการค้า
HIYI
ที่มา
China
รหัสพิกัดศุลกากร
9027899090
กำลังการผลิต
9999

คำอธิบายสินค้า

Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery

OVERVIEW

SafeVac 4L Vacuum-Controlled Aspiration System
 
Safe and efficient system for labs handling critical or biological liquid waste.
Vacuum power can be set to different levels to achieve 1mL/S to 15mL/ S aspiration speed Sensitive level sensor to prevent liquid overflow during operation Fully autoclavable waste collection bottle, tubing and handle Lid, tubing and handle are easy for disassembling, cleaning and autoclaving Wide range of adapters to fit tube, microplate and disk plate for various tasks
Interchangeable hand operator -tip adapters make it suitable for various tasks from single channel to 8-channel based on the applications in tube, micro plate, disk plate etc.
Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery
 

Product Feature

* Compact, user-friendly design
* Level detection system prevents bottle overfill
* Control knob for vacuum setting
* The parts in contact with liquids are autoclavable
* Easy to disassemble and clean
* Ideal tool to avoid lab air contamination and protect personnel safety
* adjustable vacuum level with indicator light is designed for various


Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery
Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery

Specification

SWide range of adapters to fit well with different tubes, microplate and disk plate, all of which can be fully autoclaved (At 121ºC 1 bar for 20 minutes. After autoclaving the equipment must be cooled down before use).
 
 
 
Specifications
SAFEVAC
Vacuum range
0-600mbar
Aspirating speed
1-15mL/S
Flow rate [liquid]
17mL/s
Autoclave Component
tube; waste bottle; operation handle;
Dimension[W×D×H]
180×240×450mm
Weight
3kg
Input voltage
100-240VAC, 50/60 Hz
Bottle Volume
4L
Cat. No.
P/N
Descriptions
Power supply
7035100000
SAFEVAC
Vacuum Aspiration System
USA plug,100V-220V/50Hz/60Hz
SAFEVAC
Vacuum Aspiration System
Cn plug,100V-220V/50Hz/60Hz
SAFEVAC
Vacuum Aspiration System
Euro plug,100V-220V/50Hz/60Hz
SAFEVAC
Vacuum Aspiration System
UK plug,100V-220V/50Hz/60Hz
 
Cat. No.
Descriptions
17900115
PPCO Vacuum Bottles - 4L 83B
17100556
Single needle Φ1.5mm, 40mm
17100557
Single needle Φ1.5mm, 120mm
17100602
Single needle Φ2.5mm, 40mm
17100603
Single needle Φ2.5mm, 120mm
17100360
8 channel needle Φ1.5mm
17100578
tip detrusion adapter 200ul tip
17900150
tip detrusion adapter 1ml tip
17100577
8-channel tip detrusion adapter 200ul tip
17100301
Hydrophobic filter 0.45um,1pc/pk
17900127
SAFEVAC Handle bracket

Application Scenes

For laboratory waste recovery and separation of liquid and solid. It can be widely used in cell culture,
DNA extraction, microplate waste removal, and any other liquid separation or recovery.
Best replacement for the common vacuum pump, for all kinds of waste liquid recovery, especially biological, chemical and radioactive liquids.

FAQ

Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery

 

Company Profile


Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery

Certifications

Hiyi Safevac 4L Vacuum-Controlled Aspiration System for Laboratory Used in Any Other Liquid Separation or Recovery

ส่งข้อซักถามของคุณไปยังผู้ให้บริการนี้โดยตรง

*ของ:
*ถึง:
*ข้อความ:

โปรดป้อนตัวอักษรระหว่าง 20 ถึง 4000 ตัว

นี้ไม่ใช่สิ่งที่คุณตามหา? โพสต์คำขอการจัดซื้อตอนนี้

สิ่งที่คุณอาจจะชอบ

กลุ่มผลิตภัณฑ์

ติดต่อซัพพลายเออร์

สมาชิกระดับโกลด์ อัตราจาก 2024

ซัพพลายเออร์ที่มีใบอนุญาตการทำธุรกิจ

บริษัทการค้า
จำนวนของพนักงาน
6
ปีที่ก่อตั้ง
2018-05-24