Model:PC60B24429F
Impeller Sizes: from 30mm to 80mm diameter;
Sound Level: from 32dBA to maximum 48dBA according different rotation speed;
Airflow: maximum to 600CMH, Cubic Meter per Hour, equal to approx. 353CFM , Cubic Feet per Minute;
Air Pressure: Maxim to 80Pa, equal to 8.16mm H2O and to 0.32 inches H2O;
Power: Maximum motor input power goes to 100W motor diameter 80mm.
General Characters:
1-1 | Rated Voltage | 24 VDC |
1-2 | Operating Voltage | 16 ~ 28 VDC |
1-3 | Rated Speed | 1800 RPM |
1-4 | Input Current | 0.73 A |
1-5 | Input Power | 17.52 W |
1-6 | Acoustical Noise | 42 dB(A) |
1-7 | Life Expectance | 50,000Hours(L10) At 40ºC room, humidity 15%~65%RH. |
1-8 | Direction of Rotation | Clockwise seen on motor |
1-9 | Insulation Class | Class B |
1-10 | Insulation Resistance | 50 Mega Ohm minimum at 500VDC Between frame and (+) terminal |
1-11 | Motor Protection | Locked rotor protection Polarity protection Automatic restart capability |
1-12 | Speed Control | Control input 0~10VDC |
1-13 | Dielectric Strength | 5mA maximum at 500VAC 50Hz five second Between frame and (+) terminal |
1-14 | Air Flow | 149.48 CFM / 254 m3/H |
1-15 | Static Pressure | 3.67 mmH2O / 36 Pa |
1-16 | Protection Type | IP44 |
Environmental Characters:
2-1 | Dimension | 90 x 98 x 492 (see dimension drawing) |
2-2 | Material of Impeller | Aluminum alloy |
2-3 | Number of Blades | 22 |
2-4 | Bearing System | NMB ball bearing |
2-5 | Mounting Position | Any |
2-6 | Lead Wire | Red , Black, White AWG22# |
2-7 | Package | Standard |
Electrical Protection
3-1 | Locked-rotor Protection | Over-current limiting circuit protects motor from damage at least for 72 hours of locked rotor condition at rated voltage. |
3-2 | Reverse Polarity Protection | No damage if the positive and negative leads are reversed under maximum operation voltage conditions. |
3-3 | Over Voltage Protection | The circuit will be shut down automatically when input voltage over 15VDC. And re-started when Voltage down to 15VDC below. |
3-4 | Soft Start | In 5 seconds after power on and speed control voltage gets to 1.5V. |
3-5 | RoHS | All the material meets RoHS standard. |
Environmental Characters
4-1 | Operating Temperature | -25ºC to 60ºC |
4-2 | Storage Temperature | -40ºC to 75ºC |
4-3 | Operating Humidity | 5% to 90% RH |
4-4 | Storage Humidity | 5% to 95% RH |
4-5 | RoHS | All the material meets RoHS standard. |
Performance Curve:
Testing Condition
Input Voltage----Operating voltage (24 VDC)
Temperature-----Room temperature
Humidity---------65%RH
Test distance-----1m
Outline Drawing
Note
1. Connection line 3X (Red, Black, White AWG22#);
Red=+24VDC, White=0-10VDC, Blue=GND.
Safety Requirements
Products of the same series
Model Part No. |
Rated Voltage VDC |
Air Flow M3/H |
Air Pressure Pa |
Rated Speed RPM |
Sound Level dB(A) |
Total Length mm |
PC60B12123F | 12 | 102 | 52 | 2600 | 45 | 186 |
PC60B24123F | 24 | 102 | 52 | 2600 | 45 | 186 |
PC60B12184F | 12 | 139 | 47 | 2400 | 46 | 246 |
PC60B24184F | 24 | 139 | 47 | 2350 | 45 | 246 |
PC60B12245F | 12 | 169 | 43 | 2200 | 45 | 307 |
PC60B24245F | 24 | 169 | 43 | 2200 | 45 | 307 |
PC60B12306F | 12 | 192 | 41 | 2100 | 43 | 368 |
PC60B24306F | 24 | 192 | 41 | 2000 | 43 | 368 |
PC60B12368F | 12 | 212 | 41 | 2000 | 43 | 430 |
PC60B24368F | 24 | 212 | 38 | 1900 | 42 | 430 |
PC60B12429F | 12 | 254 | 38 | 1900 | 42 | 492 |
PC60B24429F | 24 | 254 | 36 | 1800 | 42 | 492 |